Permit: T01CM03565

Parcel: 141146870

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/27/2001 FRAMING Approved IVRS - Inspection 0000*
09/26/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) REMOVE RADIANT FROM GARAGE RIDGE LINE
09/25/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) ONE AND TWO AND HALF OF THREE NOT DONE FROM 9/21/01 INSPECTION
09/21/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) SEAL WATER MAIN PROTRUSION-MESH 2) FINISH RADIANT BARRIER INSTALLATION AT BAFFLED TOP PLATES 3) REMOVE RADIANT MATERIAL FROM FLUE AND GARAGE RIDGE LINE
09/19/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) NUMBERS 1, 2, 5, 7 AND 8 FROM 9/17/01 INSPECTION NOT DONE
09/17/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) REMOVE RADIANT PAPER MATERIAL FROM FLUE 2) STRAP TOP PLATES AT NORTH GARAGE WALL 3) FHA STRAP MAIN GAS RISER 4) FHA STRAP SOUTH GABLE TOP PLATE AT PLUMBING VENT (NOT BANG) 5) SHIM HEADERS WHERE NEEDED 6) FHA STRAP SOUTHWEST CORNER HOUSE BIB BOTTOM PLATE 7) SEAL HOLES IN SOUTH BAY BOTTOM PLATE 8) FINISH RADIANT BARRIER INSTALLATION AT WALL TOPS (CEILING) 9) NEED RECONFIGURATION OF ATTIC VENTILLATION SINCE RADIANT INSTALL 10) GROUT HALL TUB AND MASTER SHOWER 11) NO WATER PRESSURE