Permit: T01CM03554

Parcel: 137313380

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/18/2001 FRAMING Approved IVRS - Inspection 0000*
09/13/2001 FRAMING Denied IVRS - Inspection 0999$/ 1) GAS LINE NOT INSTALLED AS PER PLAN SIZE AND LOCATION. PROVIDE OR REVISE PLAN/SITE SPECIFYING AS BUILT 2) MULTIPLE ROMEX CABLES SECURED ON EDGE PROTECT THRU-OUT WHERE WITHIN 1 1/4 FROM EDGE OF STUDS VERTICAL AND HORIZONTAL 3) SECURE ROMEX WITHIN 12 INCHES OF BOXES, PANEL AND ALL FIXTURES 4) DRAG TRUSS AT ENTRY TOP CHORD KNOTCHED FOR OUT RIGGERS PROVIDE FIX MAY REQUIRE ENGINEER'S FIX 5) KINKED REFRIGERENT LINES 6) DUCT NOT SIZED PER PLAN