Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/30/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/28/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PROVIDE DOUBLE STP AT GIRDERS 2) PROVIDE STRAPS AT DOUBLE 2 X 12 AT FRONT 3) PROVIDE L-50 CLIP AT LEDGER PER PLAN 4) NAIL ROOF AT INTERIOR BRG WALL BLOCKING 5) PROVIDE H CLIPS AT ROOF SPANS OVER 16" ON CENTER BETWEEN TJI'S 7) PROVIDE FIX FOR JACK TRUSS AT HIP REVERSED 8) BAY NOT COMPLETE