| 12/19/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 12/18/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE PROOF OF ELECTRIC, PLUMBING, GAS AND MECHANICAL APPROVAL 2) UNLABELED 7TH BREAKER FROM LEFT TOP 20 AMP ON 14999 WIRE 3) ACCESS TO A/C DISCONNECTS OBSTRUCTED BY UNIT. REQUIRES 30" X 30" WORK SPACE IN FRONT OF DISCONNECTS 4) GFCI OUTLET REQUIRED WITHIN 24" OF RIGHT SIDE OF SINK 5) SMOKE DETECTOR REQUIRED IN BEDFROOM 3 MISSING 6) ELECTRIC OUTLETS IN GARAGE MUST BE AT LEAST 18" ABOVE FLOOR |
| 12/17/2001 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) LOCKED |