Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM03528
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/19/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
09/18/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) BLOCK AROUND MECHANICAL DUCTS 2) TIGHTEN LOOSE EXPANSION BOLTS 3) #5 SHEARWALL MISSING ANCHOR BOLTS AT 24 INCHES ON CENTER 4) SEAL PENETRATION AT SOLE PLATE TO WEEP SCREED 5) COMPLETE ROMEX CABLE AND PROTECT THRU OUT 6) COMBUSTIBLE MATERIAL IN DIRECT CONTACT WITH FURNACE FLUE PIPE |