Permit: T01CM03508

Parcel: 205661340

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/22/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/09/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) REPAIR BEAM SUPPORT AT SOFFIT NEAR FAU VENT 2) NO GAS PRESSURE TEST 3) PARTIAL ON 1025 PENDING #3 SHEARWALL COMPLETION 4) OK-TO INSULATE
09/20/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ANCHOR BOLTS AT #2 AND #3 SHEARWALLS MUST BE 5/8" DIAMETER 24" ON CENTER (SEE SHEARWALL SCHEDULE) 2) PROVIDE ENGINEER APPROVED FOR ALTERNATE HD AT GREAT ROOM WINDOW 3) SOME HOLDOWNS MISSING 4) #3 SHEARWALLS CALL FOR PLYWOOD BOTH SIDES
09/05/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) LEDGER ATTACHMENT OK