Permit: T01CM03505

Parcel: 115220490

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
01/08/2002 ELECTRIC - FINAL Approved IVRS - Inspection 0000*OK FINAL.
01/03/2002 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*1.) PLEASE PROTECT BULB FROM CONTACT OVER SHELF IN LAUNDRY ROOM 2.) A/C DISCONNECTS NEED TO BE LABELED AND TIGHEN LOOSE SEALTITE FITTINGS. 3.) A STRAIN RELIEF CONNECTOR IS REQUIRED AT THE HOOD 373-5. 4.) DO NOT WRAP GROUND WIRE AROUND SCREW MORE THAN 3/4 OF A TURN - NOT MULTIPLE WRAPS.5.) GROUND AND NEUTRALS DOUBLE LUGED AT SERVICE.