Permit: T01CM03505

Parcel: 115220490

Inspection Status: Approved

Inspection History: ELECTRIC - UNDERGROUND

Date Description Inspector Results Comments
01/08/2002 ELECTRIC - UNDERGROUND Approved IVRS - Inspection 0000*
10/19/2001 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*OK ROUGH ELECTRIC OK CABLE DROP & TEMP SERVICE UNIT #1 ONLY.
10/16/2001 ELECTRIC - UNDERGROUND Denied IVRS - Inspection 0999*1.) NEED CONNECTOR WHEN ENTERING BOXS LARGER THAN SINGLE GANG 373.5. 2.) SECURE NM CABLE WITHIN 12" AS PER CODE. 3.) NEED BOX AT BATH LIGHT. 4.) NEED CONNECTOR AT EXHAUST FANS. 5.) BOND SERVICES TOGETHER 250-58. 6.) NEED PEMANENT METAL ADDRESS LABELS. 7.) USE APPROVED FITTING TO ATTACH BELL BOX. 8.) CORRECTLY SECURE CABLES ABOVE PANEL 9.) FIRE SEAL NM CABLE AT WALL CORNERS.