Permit: T01CM03501

Parcel: 137055180


Addresses:

1169 W IRVINGTON RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM03501

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/27/2001 PLUMBING - INTERMEDIATE Approved 1.) CAR WASH INTERMEDIATE OK (ALL EXPOSED) 2.) CAR WASH FINAL OK PENDING ANY OTHER INSPECTIONS.3 .) PLUMBING FINAL FOR SERVICE STATION OK 4.) ALL RPBP CERTIFIED OK ON FILE OF TUCSON WATER. 5.) OK FOR C OF O. PENDING ANY OTHER INSPECTIONS.
11/20/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) BLDG SEWER FROM BLDG DRAIN TO 1-10 FEET FROM PROPERTY LINE OK CAR WASH AND MAIN BLDG OK BACKWATER VALVES OK NEED TO SEE COVERS 2.) OK TO BACKFILL.
11/14/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) FINAL CONNECTIONS AT ISLANDS FOR GUTTER DRAINS OK OK TO COVER.
11/09/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) ABS DWV OK WATER TEST OK 2.) COPPER OK PRESSURE TEST OK CHECK SUBMITTALS TO VERIFY CHECK VALVES IN TEMPORARY VALVE.3.) ROOF DRAINS OK WATER TEST OK 4.) AREA DRAINS FOR CANOPY OK TO CATCH BASIN OK OK TO COVER NEED TO SEE CONNECTION.
11/04/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) CONTRACTOR TO INSURE THAT ALL PIPING EMBEDDED IN CONCRETE TO BE WRAPPED. 2.) FLOOR DRAINS, SINKS, AND TRAP PRIMERS OK 3.) OK TO POUR.
11/01/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) AREA DRAINAGE FOR CATCH BASIN A,B, & C. OK INSTALLED PER PLAN OR REDLINED AS INSTALLED 2.) CATCH BASINS FORMEL AND READY TO POUR 3.) OK TO BACKFILL.
10/30/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*2.) WATER TEST OK 3.) OK TO BACKFILL 4.) 6" SDR 35 ONE LINE, WEST SIDE TO WASH OK OK TO BACKFILL.
10/24/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) FLOOR SINKS AND DRAINS,TRAP PRIMERS PIPE WRAP OK 2.) OK FOR CONCRETE.