Permit: T01CM03491

Parcel: 120010750

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM03491

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/30/2001 FRAMING Approved IVRS - Inspection 0000*
08/28/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) ISOLATE BACK TO BACK RECEP BOXES AT GARAGE TO HOUSE FIRE WALL 2) BLOCK BLOWN OUT SHEARWALL AT GARAGE 3) ANCHOR BOLTS EXPANSION BOLTS AND HOLDOWNS ARE LOOSE THRU-OUT SEE MANUFACTURERS SPECIFICATIONS FOR HOLDOWN TIGHTENING SPECIFICATIONS 4) SCREEN AT DRYER VENT T-TOP 5) PROVIDE ANCHOR BOLTS WITHIN TWELVE INCHES OF SOLE PLATE SPLICES INCLUDING INTERIOR SHEARWALLS 6) ALL HOLDOWNS NOT NAILED WITH 16D'S AS PER MANUFACTURERS SPECIFICATIONS 7) SOLE PLATE CRACKED IN HALF PROVIDE FIX OR REPLACE PROVIDE EQUIVALENT INTEGRITY 8) BE ADVISED ELECTRICAL RECEP BOXES ARE EQUIPPED WITH LOCKING/SEALING DEVICE DON NOT REMOVE SEE MANUFACTURERS SPECIFICATIONS
08/27/2001 FRAMING Partial Approval IVRS - Inspection 0000*NO WATER TEST 2.) REMOVE SCREEN FROM DRYER VENT.