Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM03491
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
08/28/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) ISOLATE BACK TO BACK RECEP BOXES AT GARAGE TO HOUSE FIRE WALL 2) BLOCK BLOWN OUT SHEARWALL AT GARAGE 3) ANCHOR BOLTS EXPANSION BOLTS AND HOLDOWNS ARE LOOSE THRU-OUT SEE MANUFACTURERS SPECIFICATIONS FOR HOLDOWN TIGHTENING SPECIFICATIONS 4) SCREEN AT DRYER VENT T-TOP 5) PROVIDE ANCHOR BOLTS WITHIN TWELVE INCHES OF SOLE PLATE SPLICES INCLUDING INTERIOR SHEARWALLS 6) ALL HOLDOWNS NOT NAILED WITH 16D'S AS PER MANUFACTURERS SPECIFICATIONS 7) SOLE PLATE CRACKED IN HALF PROVIDE FIX OR REPLACE PROVIDE EQUIVALENT INTEGRITY 8) BE ADVISED ELECTRICAL RECEP BOXES ARE EQUIPPED WITH LOCKING/SEALING DEVICE DON NOT REMOVE SEE MANUFACTURERS SPECIFICATIONS | |
08/27/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*NO WATER TEST 2.) REMOVE SCREEN FROM DRYER VENT. |