Permit: T01CM03490

Parcel: 120010700

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM03490

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/30/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
08/28/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) HOT WATER FLUE PIPE NEEDS TO BE SECURED AT MID SPAN, PROVIDING 1 INCH CLEARANCE 2) RECEP BOXES NEED TO BE FLUSH WITH DRYWALL THRU-OUT 3) LOOSE EXPANSION, ANCHOR AND HOLDOWN BOLTS 4) PROVIDE BRACING AT BOTTOM CHORD OF TRUSSES WHERE DEADWOOD IS ATTACHED 5) TC CLIPS NOT NAILED PER SPECIFICATIONS 6) ALL HOLDOWNS ARE NAILED WITH THE WRONG SIZE FASTENERS SEE SIMPSON MANUFACTURERS REQUIREMENTS SHOULD BE 16D'S 7) SUPPORT POSITIVELY TRANSFER DUCTS SUB STANDARD INSTALLATION
08/27/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*NO WATER TEST.
08/23/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*