Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM03484
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/16/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/14/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT GAS MAIN AND REAR GARAGE WALL 2) LOOSE ANCHORS AND REDHEADS 3) STRAP INTERSECTING TOP PLATES INSIDE FRONT ENTRY 4) SHIM STAIR PLATFORM HEADER TRIMMERS 5) SHIM HEADERS WHERE NEEDED 6) SHIM GLUE-LAM BRACKET SIDES WHERE NEEDED 7) PLUMBING NOT FINISHED FOR TUBS, 1ST FLOOR CEILING 8) NEED H2.5 AT 1 JOIST AT STAIRS-NORTH OF FIREPLACE IN HALL 9) INSTALL BETTER TRUSS X BRACING IN GARAGE 10) REMOVE ROOFING FROM FLUE |