Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ENGINEERING - FINAL
Permit Number - T01CM03462
Inspection Description - ENGINEERING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/15/2005 | ENGINEERING - FINAL | Approved | THIS SITE WAS CHECKED AND FOUND TO BE SUBSTANTIALLY COMPLETE, WITH MINOR DRAINAGE ISSUES TO BE RESOLVED UNDER THE NEW CONTRACT. THE SCHOOL WILL BE INSTALLING ADDITIONAL SIDEWALK SCUPPERS AS NEEDED DURING THE CONSTRUCTION PHASE OF THE NEW CLASSROOMS. ALSO IT WAS NOTED THAT THE ON-SITE DETENTION/RETENTION BASINS ARE NOT OPERATING PER OUR DEVELOPMENT STANDARDS AND STORMWATER RET./DET. MANUAL IN REGARDS TO THE PERCOLATION RATES. THE NEW CONTRACTOR WILL WORK ON REMOVING THE SEDIMENT FROM THE BASINS TO HELP RE-ESTABLISH THE PERCOLATION RATES. THE SCHOOL WILL INVESTIGATE THE INSTALLATION OF A LOW FLOW PIPE TO ALLOW FOR CONTINOUS DISCHARGE OF THE WATERS OVER TIME. |