Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T01CM03462
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/16/2002 | ROOF NAILING | Approved | IVRS - Inspection 0000* | |
03/18/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*PARTIAL MAIN ENTRANCE PANEL OK LIBRARY TRUSS BRACES OK. | |
03/14/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*ROOF PARTIAL STEEL DECK FASTENING ON HIGH ARCHES OK. | |
03/11/2002 | ROOF NAILING | Partial Approval | ||
03/05/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*EAST END | |
02/28/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*ROOF NAILING 1 TGI COMPLETE EXCEPT FOR NEED HANGER @ LEADER IN 185. 2.) I WOULD STILL LIKE DETAIL FOR INTERAL BRACING OF TRUSS IN LIBRARY. | |
02/20/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*WEST 1/2 LIBRARY DECK ON I STILL NEED FOR APPROVED DECK WELDS STEEL. I NEED CLARIFICATION OF GN2 ON TRUSS DETAIL | |
02/15/2002 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection 0000*NO ACCESS TO ROOF. | |
02/12/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*ALL REQUIRED WEB STIFFNERS INSTALLED. | |
02/06/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000* | |
02/05/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*DECK NAILING ONLY WEB STIFFNERS FOR TGTS STILL MISSING IN NOT PLACES. | |
01/28/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*DECK NAILING SW ROOF AREA | |
01/23/2002 | ROOF NAILING | Denied | IVRS - Inspection 0999*1.) INSTALL WEB STIFFNERS ON TGI AS PER APPROVED PAN. 2.) PROVIDE STAMPED RFI FOR USE OF TRUSSES INCLUDING USE OF TGI HANGER FOR TRUSSES. 3.) FINISH NAILING PATM25 STRAPS TO JOISTS IN EAST ENTRY TO ROOM 122. | |
01/18/2002 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection 0000*NOT READY ARRIVED 5:15PM SITE LOCKED. SORRY I'M SO LATE. I'LL RETURN ON TUESDAY AS C.O.T. IS CLOSED MONDAY FOR MLK. | |
01/09/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000* | |
01/03/2002 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*PARTIAL 134,131,136,137, | |
12/19/2001 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*PARTIAL WEST ROOM 1.) DIAPHRAGM BLOCKING IN OTHER AREAS MUST BE CORRECTED 2.) DO NAILS NEED TO BE BENT OVER ON STRAPPING. | |
12/18/2001 | ROOF NAILING | Partial Approval | IVRS - Inspection 0000*PARTIAL (POD #1) |