Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM03462

Parcel: 119280310


Addresses:

2700 S LA CHOLLA BL


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T01CM03462

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
05/16/2002 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
03/05/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
02/28/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
02/20/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*INFILL AND SOUTH SIDE 156,158,159,173,172
02/15/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL 2ND & 3RD LIFTS AT SOUTH PIERS; 1ST LIFT EXTERIOR INFILL.
02/12/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*MECH SCREEN TOW; 4-8' SOUTH FILL SECTION & SHEAR; BEAM PLACEMENT.
02/07/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL MECH ROOM STEMWALL TOW EASTEND IL ROOM 156 @ SHEAR PANELS.
02/06/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*TOW EAST END.
02/05/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*EAST END & INFILL TOW -12'
01/31/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL EAST END AND IN FILL AREAS 5'-12'
01/28/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PREGROUT PARTED.
01/23/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
01/17/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*12 & TOW EAST AREA; 1L COLUMNS @ ENTRANCE.
01/15/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*8'-18' EAST END ROOMS.
01/14/2002 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*1.) BAR SPLICES DO NOT CONFORM TO 48 BAR DIAMETER DETAIL IN SW CLASSROOM 2.) I NEED CLARIFICATION OF LAP LENGTH FOR VERTICALS OVER LINTELS IS IT 24" OR 30"
01/11/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
01/10/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
01/09/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*8' TOW KITCHEN & ASSEMBLY AREA; ARCHES ON WEST SIDE.
01/08/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*KITCHEN 8' TOW VARIOUS WEST AREAS.
01/07/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL 4-8' KITCHEN AREA.
01/03/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PREGROUT EAST END 4-'8'
12/27/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL 4'-12' SOUTH CLASSROOMS.
12/19/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
12/12/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
12/10/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
12/07/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*4' - 8' SOUTH SIDE OF SECTION A.
12/04/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
11/30/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*1 1/2" THICK MORTAR JOINT@ TOW ROOM 120 & 121 COMPENSATED FOR BY MAKING 16" DEEP BOND BEAM. INSTEAD OF 8."
11/26/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*11 STAGE AREA, 12' @114,8' @ INFILL.
11/15/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*SPECIAL INSPECTION REQUIRED FOR EPOXY @ IN-FILL.
11/14/2001 REINFORCED MASONRY PRE-GROUT Partial Approval 1ST. ASSEMBLY 114 TOP OUT WEST WALL 140.
11/13/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL POURED PRIOR TO INSP.
11/08/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*4' TO TOW #114;115 (VARIES)
11/06/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
10/31/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*STEM WALL PARTIAL I NEED APPROVED EPOXY INSPECTION REPORTS BEFORE YOU POUR.
10/30/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*1L,2L SOUTH CORRIDOR.
10/26/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*EXTEND VERTICALS @ NE CORNER AT 102 INTO TOP 2.) EXTEND LAP SPLICE @ SW CORNER OF 102.
10/19/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
10/17/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL 1L WEST COMMON AREA; TOW WEST EXCEPT
10/08/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*16' AND TOW WESTERN MOST ROOMS.
10/03/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*4L WEST END.
09/28/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*2L @; 3L SW
09/26/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*2L WEST END.
09/18/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
09/13/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*1ST 2 CL 134,133,