Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T01CM03462
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/16/2002 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection 0000* | |
03/05/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
02/28/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
02/20/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*INFILL AND SOUTH SIDE 156,158,159,173,172 | |
02/15/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*PARTIAL 2ND & 3RD LIFTS AT SOUTH PIERS; 1ST LIFT EXTERIOR INFILL. | |
02/12/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*MECH SCREEN TOW; 4-8' SOUTH FILL SECTION & SHEAR; BEAM PLACEMENT. | |
02/07/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*PARTIAL MECH ROOM STEMWALL TOW EASTEND IL ROOM 156 @ SHEAR PANELS. | |
02/06/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*TOW EAST END. | |
02/05/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*EAST END & INFILL TOW -12' | |
01/31/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*PARTIAL EAST END AND IN FILL AREAS 5'-12' | |
01/28/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*PREGROUT PARTED. | |
01/23/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
01/17/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*12 & TOW EAST AREA; 1L COLUMNS @ ENTRANCE. | |
01/15/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*8'-18' EAST END ROOMS. | |
01/14/2002 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection 0999*1.) BAR SPLICES DO NOT CONFORM TO 48 BAR DIAMETER DETAIL IN SW CLASSROOM 2.) I NEED CLARIFICATION OF LAP LENGTH FOR VERTICALS OVER LINTELS IS IT 24" OR 30" | |
01/11/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
01/10/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
01/09/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*8' TOW KITCHEN & ASSEMBLY AREA; ARCHES ON WEST SIDE. | |
01/08/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*KITCHEN 8' TOW VARIOUS WEST AREAS. | |
01/07/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*PARTIAL 4-8' KITCHEN AREA. | |
01/03/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*PREGROUT EAST END 4-'8' | |
12/27/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*PARTIAL 4'-12' SOUTH CLASSROOMS. | |
12/19/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
12/12/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
12/10/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
12/07/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*4' - 8' SOUTH SIDE OF SECTION A. | |
12/04/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
11/30/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*1 1/2" THICK MORTAR JOINT@ TOW ROOM 120 & 121 COMPENSATED FOR BY MAKING 16" DEEP BOND BEAM. INSTEAD OF 8." | |
11/26/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*11 STAGE AREA, 12' @114,8' @ INFILL. | |
11/15/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*SPECIAL INSPECTION REQUIRED FOR EPOXY @ IN-FILL. | |
11/14/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1ST. ASSEMBLY 114 TOP OUT WEST WALL 140. | |
11/13/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*PARTIAL POURED PRIOR TO INSP. | |
11/08/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*4' TO TOW #114;115 (VARIES) | |
11/06/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
10/31/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*STEM WALL PARTIAL I NEED APPROVED EPOXY INSPECTION REPORTS BEFORE YOU POUR. | |
10/30/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*1L,2L SOUTH CORRIDOR. | |
10/26/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*EXTEND VERTICALS @ NE CORNER AT 102 INTO TOP 2.) EXTEND LAP SPLICE @ SW CORNER OF 102. | |
10/19/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
10/17/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*PARTIAL 1L WEST COMMON AREA; TOW WEST EXCEPT | |
10/08/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*16' AND TOW WESTERN MOST ROOMS. | |
10/03/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*4L WEST END. | |
09/28/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*2L @; 3L SW | |
09/26/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*2L WEST END. | |
09/18/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
09/13/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*1ST 2 CL 134,133, |