Permit: T01CM03462

Parcel: 119280310


Addresses:

2700 S LA CHOLLA BL


Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Permit Number - T01CM03462

Inspection Description - STEM WALL/RETAINING WALL

Inspection Status - Approved

Date Description Inspector Results Comments
05/16/2002 STEM WALL/RETAINING WALL Approved IVRS - Inspection 0000*
04/03/2002 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*KINDER ENCLOSURE.
03/29/2002 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*1.) SCREEN WALL FOOTING OK 2.) LIGHT POLE BASE BY CONST. TRAILER MUST HAVE ENGINEERED FIX DUE TO HONEY COMBING AND IMPROPER PLACEMENT OF REBAR.
03/26/2002 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*LIGHT POLE BASES
01/07/2002 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*
12/07/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*F-4 FOOTERS OK PROVIDING FINISHED STEM GRADE IS LOWERED TO ACCOUNT FOR PLACEMENT OF #3 TIES.
12/04/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*BY BATHROOMS OFF ASSEMBLY AREA. 2.) MASONRY LOOKS GOOD KEEP GOING.
11/29/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*PARTIAL CLEAN REBAR BEFORE PAVING
11/27/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*CLEAN EXCESSIVE CONCRETE FROM VERTICAL BARS.
11/15/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*PARTIAL PROVIDE EPOXY REPORT.
10/31/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*
10/26/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*
10/19/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*PARTIAL SW SECTION.
10/08/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*PARTIAL PROVIDE CONTINUOUS REBAR INTO EXISTING STEM WALL @ ROOM 159 & 162.
10/01/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000$PA @ S.E. CORNER.
09/25/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*
09/18/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*
09/13/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*PARTIAL
09/07/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*PROVIDE CONTINUOUS REBAR EAST WALL OF CLASSROOM 130.
08/28/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*PROVIDE 30" OVERLAP @ ZIG ZAG
08/24/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*MAKE SPLICES WITH 3" OVERLAP BEFORE POUR.
08/21/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*
08/16/2001 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*