Permit: T01CM03462

Parcel: 119280310


Addresses:

2700 S LA CHOLLA BL


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T01CM03462

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
12/19/2001 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
12/07/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*BATHROOM REPAIR OK.
12/05/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*FOOTERS IN BATH BEING EPOXIED.
11/08/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval PER LEE RAY MECH. PADS OK .
10/26/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*1.) FINISH LAYING REBAR & TOE DOWN BY KITCHEN.
10/19/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
10/08/2001 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*DENIED 1.) NON CONTINUOUS REBAR IN FL FOOTING @ ENTRANCE TO EAST ASSEMBLY 2.) NON CONTINUOUS REBAR @ FL FOOTEN FRONT OF BOYS/GIRLS BATHROOM BY EAST ASSEMBLY AREA.
10/01/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000$PA @ S.E. CORNER.
09/25/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
09/18/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*EAST AREA
09/13/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
09/05/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
08/31/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*NOTE READY GATES LOCKED COULD NOT ACCESS FOR INSPECTION.
08/30/2001 EXCAVATION/LAYOUT REBAR & ZON Denied SEE DETAIL #6 ON PAGE 54.
08/29/2001 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*DENIED YOU NEED 30" LAPS @ SPLICES.
08/22/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*EAST OF MAIN ENTRANCE.
08/21/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*
08/16/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*STEM WALL 115,120 FOOTER 130
08/13/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*STEM WALLS WEST END.
08/09/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*CLASSROOM 143,145.
08/08/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000$NO AP PLANS AVAILABLE.
08/06/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*125,129,110,NORTH 120,119, 115
08/02/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*EXT. FOOTING @ ROOM 133, 134,131,136,143, N,W, & PART OF S) 123 (N PART OF E, PART OF W) 125(N PART OF E, PART OF S WEST
08/01/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*1.) COMPLETE THE F-2'S 2.) PROVIDE 8" BETWEEN VERTS @ MCJ'S AND CORNERS 3.)PROVIDE 12" THICKNESS.