Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/10/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/07/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) DOUBLE BEARING 2 X 4 OVER NOTCHED 2) MISSING AB MASTER BEDROOM 3 AREAS 3) MISSING FLAPPER AT EXHAUST FAN 4) NAIL CLIPS AT SHEAR TRANSFER 5) MISSING LTT20 AT MASTER BEDROOM |
| 09/06/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PLUMBING INCOMPLETE 2) SAN-TEC IN HORIZONTAL POSITION NOT PERMITTED 3) MAXIMUM NOTCH IN BEARING 2 X 4 IS 7/8" 4) REPLACE WATER HEATER T&P LINE WHERE HIT WITH DRILL 5) NAIL PROTECT ELECTRIC HOME RUNS AT BLOCKING 6) TEMP ELECTRIC OUTLET NOT INSTALLED |