Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/17/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 08/16/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE 2 X DOUBLE TRIMMERS WHERE HEADERS THAT EXCEEDS 2 X 8 SEE PLAN HEADER SCHEDULE 2) PROVIDE DETAIL 7/DT1 AT SHEAR STUBBED TRUSSES 3) SECURE EXTERIOR DOUBLE TOP PLATES NOT CABIN TIED 4) BLOCK UNSUPPORTED SHEAR PANELS AT GABLE ENDS 5) PROVIDE ADDITIONAL HOLDOWN DEVICE AT GARAGE FRONT WALL PA42'S NOT EQUIVALENT TO HD2A'S 6) PROVIDE TWO EXPANSION BOLTS PER SINGLE SOLE PLATES 7) LEAVE CITY OF TUCSON APPROVED TRUSS CALC'S ON SITE |