Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 07/17/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 07/12/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) EXPOSE FOOTING ON NORTH AND WEST WALLS TO A DEPTH OF 12" FOR FOOTING INSPECTION, IF NO FOOTING EXISTS UNDERMINE SLAB 12" X 12" INSTALL TWO EACH #4 REBAR 3" ABOVE GROUND AND CALL FOR INSPECTION 2) EXTERIOR SIDING AND UNTREATED WOOD ARE IN CONTACT WITH SOIL PROVIDE 6" SEPERATION BETWEEN SIDING AND SOIL AND PROVIDE 2 PERCENT GRADE SLOPE AWAY FROM HOUSE FOR 5' 3) BASBOARD HEATER MUST BE ON A SEPERATE DEDICATED 20 AMP CIRCUIT |