Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM03385

Parcel: 125041810


Addresses:

2403 E 2ND ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
02/28/2002 ROOF NAILING Approved IVRS - Inspection 0000*
02/20/2002 ROOF NAILING Denied IVRS - Inspection 0999*/ 1) ROOF NAIL REQUIRES ENDS AND EDGES AT 6" ON CENTER WITH 8D NAILS OR STAPLES PROVIDE SAMPLE OF STAPLES USED-PRESENTLY SPACED IN EXCESS OF 6" ON CENTER 2) PLAN CALLS FOR THRU LEDGER BOLTS AT 16" ON CENTER "J" BOLTS USED AT 24" ON CENTER 3) PLAN CALLS FOR BLOCKING OF TRUSSES AT 1/3 X 2/3 SPACING 4) PLAN CALLS FOR WEB STIFFINGERS. BUILD TO PLAN OR REVISE PLAN TO AS BUILT AND HAVE APPROVED