Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/28/2002 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 02/20/2002 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) ROOF NAIL REQUIRES ENDS AND EDGES AT 6" ON CENTER WITH 8D NAILS OR STAPLES PROVIDE SAMPLE OF STAPLES USED-PRESENTLY SPACED IN EXCESS OF 6" ON CENTER 2) PLAN CALLS FOR THRU LEDGER BOLTS AT 16" ON CENTER "J" BOLTS USED AT 24" ON CENTER 3) PLAN CALLS FOR BLOCKING OF TRUSSES AT 1/3 X 2/3 SPACING 4) PLAN CALLS FOR WEB STIFFINGERS. BUILD TO PLAN OR REVISE PLAN TO AS BUILT AND HAVE APPROVED |