Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/19/2002 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*1.) ABS DWV OK 2.) COPPER WATER OK PRESSURE TEST OK 3.) TUBS OK 4.) CLOSET FLANGES OK 5.) GAS PIPE OK PRESSURE TST OK 6.) OK TO COVER WALL. |
| 04/17/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999* |
| 04/15/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0666*1.) SEPARATE GAS PIPING FROM COPPER PIPING. 2.) REVIEW HANGERS AND SUPPORTS 3.) REMEMBER, WHENEVER YOU CHANGE THE ROUGH- IN BELOW 42", THE NEW, OR REVISED SECTION, MUST BETESTED TO 42". 4.) CLOSET RINGS OK 5.) NOT ALL TUBS FULL OF WATER. 6.) HORIZONTAL ABS TO BE SUPPORTED 4' MAX 7.) COPPER LOCKING MINIMUM SUPPORT 8.) GAS TO BE STRAPPED PER 94 UPC. |