Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM03352

Parcel: 11207103E


Addresses:

2721 E ALTURAS ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/06/2001 FRAMING Approved IVRS - Inspection 0000*
09/13/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) INADAQUATE NEUTRAL LIGHT FLOOR AREA 1230 SQUARE FEET. HOUSE HAS 84 SQUARE FEET OF NEUTRAL LIGHT 98 SQUARE FEET REQUIRED-14 SQUARE FEET ADDITIONAL REQUIRED OR PROVIDE AN ENVIORNMENTAL ENGINEERS CERTIFICATIONS OF COMPLIANCES WITH IRC SECTION 303.1 EXCEPTION 1 AND 2 2) PLUMBING NOT COMPLETE 3) OK TO ROCK ALL BUT REPAIR AREAS
08/31/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) LAUNDRY VENT NOT PROPERLY INSTALLED 2) LAV NOT PROPERLY VENTED 3) WEIR OF LAUNDRY "P" TRAP MUST BE BETWEEN 6"+18" OF FLOOR 4) ITEMS 7 AND 8 OF 8/24/01 OPEN
08/24/2001 FRAMING Denied IVRS - Inspection 0999*1.) SANITARY "T" FITTINGS ARE NOT ALLOWED IN HORIZONTAL POSITIONS. 2.) LAUNDRY "S" TRAPPED. 3.) LAUNDRY "P" TRAP WEIR CANNOT BE HIGHER THAN 18" ABOVE FLOOR AND 5 AMP PIPE MUST BE LEAST 18" IN LENGTH 4.) KITCHEN DRAIN NOT ALLOWED TO BE HEAL VENTED. 5.) SHOWER REQUIRES 2" DRAIN 6.) GROUND ALL METAL BOXES & MAKE UP ALL GROUNDS. 7.) PROVIDE PLAN REVISION FOR NATURAL LIGHT. 8.) REVISE MECHANICAL PLAN TO AS BUILT.