Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM03351

Parcel: 129133830


Addresses:

1122 E 35TH ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/13/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/13/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) MUST INSTALL OSB ON EXTERIOR WALLS PER PLAN 2) STRAP 4" X 6" AT 2" X 4" TOP PLATE BOTH SIDES 3) NEED APPROVED TRUSS DRAWINGS FROM TRUSS MANUFACTURER 4) APPEARS GABLE END TRUSS NEEDS GANG NAILS AT ADDED 2 X 4'S WOOD PLATE TO TOP OF DOUBLE TOP WOOD PLATE (OTHERWISE ADD ADDITIONAL H2.5 HURRICANE TIES 6) STRAP GABLE END TRUSS BOTTOM CHORD TO WALL BELOW