Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/27/2001 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*CORRECTION HAVE BEEN MADE TEST OK PLEASE WRAP ABS NO COPPER UNDER SLAB. |
| 09/26/2001 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*PLEASE INSTALL AS PER APPROVED DRAWING REMOVE 1/4 BEND PROVIDE SWEEPS PROVIDE TEST & CALL AGAIN. |
| 09/25/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*PLEASE HAVE YOUR PLUMBER READ OVER SEC 706.2. "REMOVE DOUBLE SAN TEC" FOR WC. SEE ABOVE SEC. ALSO HAVE PLUMBER READ OVER SEC 804.1. WE DO NOT INSTALL A TRAP FOR A CLOTHES WASHER UNDERGROUND. PLEASE PROVIDE PLUMBERS LICENSED NAME & LICENSE # AT TIME OF NEXT INSP. |