Permit: T01CM03350

Parcel: 11502173E


Addresses:

522 E ELM ST #01

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/13/2002 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
11/08/2002 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*1.) PLEASE FINISH #5 & #8 OF PREVIOUS INSPECTION.
11/05/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0999*1.) PROTECT NM CABLE IN UPPER CABINET 2.) HOOD TO HAVE AN APPROVED CONNECTOR. 3.) PLEASE USE PROPER METHOD TO INSTALL LIGHT FIXTURE BACK PORCH. 4.) LIGHT OUTLET IN LAUNDRY TO BE CAPPED PROPERLY FLUSH WITH SURFACE.
5.) PLEASE PROVIDE MANUFACTURES REQUIREMENT FOR INSTALLATION OF SMOKE DETECTORS AND DISTACE FROM CORNERS INSTALL AS PER MANUFACTURE REQUIREMENTS - 4" MIN.
6.) CLEAN SURFACE OF BUSS FROM FORIGEN MATERIAL 110-12 ALSO BREAKERS TO BE LEDGEABLE TO READ.
7.) WHERE IS CONNECTOR FOR NM CABLE ENTERIOR BOTTOM OF PANEL UNIT #1.
8.) PROTECT PVC CONDUIT ABOVE GROUND UNIT #2.