Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 05/22/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*CORRECTIONS REQUESTED ARE OK. |
| 05/20/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1. PLEASE VERIFY CIELING BOXES ARE LISTED FOR USE WITH A FAN 110-3. 2.) TIGHTEN CONNECTOR AT TOP OF PANEL AND AT METAL BOXES 373-5. 3.) WE HAVE A NM CABLE PASSING THROUGH THE SKYLIGHT OPENING. 4.) PLEASE PROTECT PVC CONDUIT AT BASE PLATE 300-4. 5.) A GAS AND WATER BOND WILL BE REQUIRED 250-104. 6.) A REFRIDERATOR CAN NOT BE ON A LIGHTING CIRCUIT 210- |
| 09/26/2001 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000* |