Permit: T01CM03328

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
02/06/2002 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
02/01/2002 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*CORRECTIONS HAVE BEEN MADE AS PER LAST REQUEST PLEASE PROVIDE APPROVED GAS VALVE FOR RANGES/IF RANGE IS BACK ORDERED PROVIDE VALVE & CAP OR PLUG. THANK CALL BACK WHEN VALVES OUR INSTALLED.
01/30/2002 ELECTRIC - FINAL Denied 1.) ELECTRICAL CODE CALLS FOR 2 CIRCUITS FOR THE KITCHEN COUNTER TOPS BOTH TO BE ON GFI THE PANEL HAS ONE FOR KITCHEN RECEPTACLES AND ONE REFRIEGERATION TWO ARE REQUIRED FOR COUNTER TOPS SAME BOTH UNITS 2.) BURY THE GROUND WIRE FROMSERVICE GOING TO GAS METERS 3.) STRAP THE SEALTITE FROM ROOF DISCONNECT GOING TO AC UNIT ON ROOF (TRAP TO BASE OF UNIT OK COULD NOT FIND APPROVED PLANS.