Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/06/2002 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 02/01/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*CORRECTIONS HAVE BEEN MADE AS PER LAST REQUEST PLEASE PROVIDE APPROVED GAS VALVE FOR RANGES/IF RANGE IS BACK ORDERED PROVIDE VALVE & CAP OR PLUG. THANK CALL BACK WHEN VALVES OUR INSTALLED. |
| 01/30/2002 |
ELECTRIC - FINAL |
|
Denied |
1.) ELECTRICAL CODE CALLS FOR 2 CIRCUITS FOR THE KITCHEN COUNTER TOPS BOTH TO BE ON GFI THE PANEL HAS ONE FOR KITCHEN RECEPTACLES AND ONE REFRIEGERATION TWO ARE REQUIRED FOR COUNTER TOPS SAME BOTH UNITS 2.) BURY THE GROUND WIRE FROMSERVICE GOING TO GAS METERS 3.) STRAP THE SEALTITE FROM ROOF DISCONNECT GOING TO AC UNIT ON ROOF (TRAP TO BASE OF UNIT OK COULD NOT FIND APPROVED PLANS. |