Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 12/14/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 12/10/2001 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*CANCEL PER FRANK VALENZUELA. |
| 11/20/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) NEED FHA STRAPS PROTECT ROMEX AS PER CODE 300-4 2.) MISSING PLASTER RING. 3.) BOX FILL HAS BEEN EXCEEDED 4.) NEED BOX AT BATH LIGHT 5.) STORAGE ROOM NOT COMPLETE 6.) FILL UNUSED OPENINGS IN METAL BOXES 7.) STRAP ROMEX AS PER CODE. 8.) SHEATHING FOR ROMEX TO BE 1/4" INTO BOXES 9.) MISSING RANGE CIRCUIT & HOOD WIRE. 10.) NO SERVICE PANELS INSTALLED. |
| 11/19/2001 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |