Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/27/2002 |
PLUMBING - ABOVE CEILING |
|
Approved |
|
| 04/18/2002 |
PLUMBING - ABOVE CEILING |
|
Partial Approval |
IVRS - Inspection 0000*OFFICE ONLY SEE NOTE LADDER. |
| 04/10/2002 |
PLUMBING - ABOVE CEILING |
|
Denied |
IVRS - Inspection 0999*1.) WATER HTR. IN CEILING EXCEEDS 8' ABOVE GROUND FLOOR WILL REQUIRE A PERMANATE FASTEN LADDER SEE SECTION: 511.2 94 UPC. 2.) WATER HTR IN CEILING REQUIRES ACCESS OF 24" X 24" SEE SECTION 511.0 94 UPC. 3.) OK FOR GRID ON REST OF CEILING IN OFFICE AREA. |