Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T01CM03203
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/21/2002 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
| 05/09/2002 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000*PLEASE HAVE ELECTRICAL CONTRACTOR CONTACT ME BEFORE NEXT INSPECTION. 1.) FINISH #5 & 9. 2.) WE HAVE A DISCONNECT IN A CLOSET UNDERNEATH THE CLOTHES ROD. | |
| 04/23/2002 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*1.) KITCHEN COUNTER RECEPTICALES TO BE GFI PROTECTED 2.) PLEASE MOVE SWITCH OUT FROM BEHIND SINK 3.) FILL UNUSED OPENINGS IN SUB PANEL. 4.) LABEL THE BREAKERS 5.) PLEASE CLEAN SURFACE OF SUBPANEL BUSSING 110-12 (C) 6.) WE HAVE MULTIPLE TERMANATIONS AT THE GROUND BAR 110-14. 7.) A CONNECTOR IS REQUIRED AT HOOD 373-5 8.) RECEPTICALE UNDER SINK IS NOT ACCESSABLE 9.) PLEASE VERIFY LICENSED ELECTRICAL CONTRACTOR. |