Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/25/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/24/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SECURE BOX FOR EXTERIOR FIXTURE 2) EXHAUST FAN'S PENETRATING TO ROOF 3) 1" CLEARANCE AT FLUE 4) SECURE ROMEX 5) BLOCK MECHANICAL REGISTERS 6) ROMEX OUT OF WALL 7) FIRE BLOCK LOWEST CEILING POINT 8) COMPLETE FRAMING AT DOOR |
| 10/22/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) 1/2" A.B.'S REQUIRED-3/8" INSTALLED IN PLACE |
| 10/16/2001 |
FRAMING |
|
Denied |
|