Permit: T01CM03189

Parcel: 123050020


Addresses:

2148 E GRANT RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
08/01/2001 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
07/31/2001 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*/ 1) CLAY PIPE NOT ALLOWED UNDER HOUSE SLAB 2) WRAP ALL ABS PLUMBING THAT WILL BE IN CONTACT WITH CONCRETE 3) VERTICAL 90 ELBOWS NOT ALLOWED IN HORIZONTAL DRAIN REPLACE AT SOUTHEAST CORNER 2" AND 4" AT EAST OF CLEAN OUT WITH LONG RADING SWEEP 4) SHOWER NOT PROPERLY VENTED
07/30/2001 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*/ 1) STATIONARY "T" FITTINGS NOT ALLOWED IN HORIZONTAL DRAINS 2) WATER CLOSET NOT PROPERLY VENTED ALSO SHOWER AND TUB NOT PROPERLY VENTED 3) VENT 90 FITTINGS NOT ALLOWED AT HORIZONTAL BENDS OR AT BOTTOM OF WASTE STACKS 4) SEWER DRAIN WASTE NOT ALLOWED TO RUN IN FOOTER 5) SEWER MUST BE 12" BELOW GRADE TO TOP OF PIPE AT EXIT OF SLAB EXPOSE ALL SEWER LINES FOR INSPECTION 6) NO INSPECTION REPORT AND OR CARD ON SITE 7) RE-INFORCING STEEL NOT PROPERLY LOCATED DUE TO LOCATION OF PLUMBING 8) YOU MUST REMOVE ALL ORGANIC MATERIAL AND INSTALL 4" OF AB FILL 9) PLUMBING WILL REQUIRE PROTECTION AT CONCRETE, PLUMBING IS NOT PER CODE 10) CLAY SEWER NOT ALLOWED UNPER BUILDING