Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 08/01/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 07/31/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) CLAY PIPE NOT ALLOWED UNDER HOUSE SLAB 2) WRAP ALL ABS PLUMBING THAT WILL BE IN CONTACT WITH CONCRETE 3) VERTICAL 90 ELBOWS NOT ALLOWED IN HORIZONTAL DRAIN REPLACE AT SOUTHEAST CORNER 2" AND 4" AT EAST OF CLEAN OUT WITH LONG RADING SWEEP 4) SHOWER NOT PROPERLY VENTED |
| 07/30/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) STATIONARY "T" FITTINGS NOT ALLOWED IN HORIZONTAL DRAINS 2) WATER CLOSET NOT PROPERLY VENTED ALSO SHOWER AND TUB NOT PROPERLY VENTED 3) VENT 90 FITTINGS NOT ALLOWED AT HORIZONTAL BENDS OR AT BOTTOM OF WASTE STACKS 4) SEWER DRAIN WASTE NOT ALLOWED TO RUN IN FOOTER 5) SEWER MUST BE 12" BELOW GRADE TO TOP OF PIPE AT EXIT OF SLAB EXPOSE ALL SEWER LINES FOR INSPECTION 6) NO INSPECTION REPORT AND OR CARD ON SITE 7) RE-INFORCING STEEL NOT PROPERLY LOCATED DUE TO LOCATION OF PLUMBING 8) YOU MUST REMOVE ALL ORGANIC MATERIAL AND INSTALL 4" OF AB FILL 9) PLUMBING WILL REQUIRE PROTECTION AT CONCRETE, PLUMBING IS NOT PER CODE 10) CLAY SEWER NOT ALLOWED UNPER BUILDING |