Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM03186
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2001 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
08/29/2001 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION NAIL OFF ALL EXTERIOR SHEATHIN, IF YOU HAVE VERTICAL MEMEBERS ON TRUSSES NAIL OSB ACCORDINGLEY FRONT OSB NOT NAILED OFF ALL SHEAR NAILING IS 16" ON CENTER STUDS, NAIL OFF ALL HORIZONTAL/VERTICAL JOINTS 2) FRONT ARCH, NOTHING TO SUPPORT BOTTOM CHORDS IT GETS STUCCO THEREFORE INSTALL RAT RUN FROM EXTERIOR OF ARCH TO EXTERIOR ENTRY WALL TOTAL OF THREE 3) FROM LAST INSPECTION FRONT GABLE IS NOT NAILED ROOF DECK | |
08/28/2001 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NAIL OFF ROOF FRONT GABLE ENTRY 2) NAIL OFF ALL EXTERIOR PLY (VERTICAL) 3) BRACE FRONT ARCH SOFFIT GETS STUCCO NO DRYWALL |