Permit: T01CM03132

Parcel: 13214001B


Addresses:

901 E 46TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
10/01/2001 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
09/17/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000PERIMETER WALK ROUGH APPROVED SOUTH AND EAST ALL EXTERIOR EXCEPT CENTER SECTION.
09/12/2001 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*FHA STAPS (WIRE PROTECTOR) REQUIRED ON ALL 2 X WALK WHERE MC CABLE TRANS VERSER STUD. 2.) COLOR CODE M.C. FOR PROPER CIRCUIT ON THE 3 PHASE SYSTEM. 3.) COPPER PIPE IN CONTACT W/M.C. CABLE. PLEASE RECALL.