Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T01CM03118
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/02/2001 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000*CORRECTIONS HAVE BEEN MADE AS PER LAST REQUEST. | |
07/31/2001 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*NOT READY ON GREASE TRAP GREAS TRAP IS 4" PLAN CALL FOR 2 PLEASE INSTALL A 2" GREASE TRAP OR PROVIDE FULL SIZE LINE TO GREAS TRAP NO TEST AT THIS TIME ON GREASE TRAP. | |
07/30/2001 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*BOTH DOORS LOCKED NO BODY AROUND 8:30 AM PLEASE CALL AGAIN. |