Inspection Status: Denied
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/22/2002 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0920*/ 1) STOOPS REQUIRED AT EXIT DOORS. STEP AT ENTRY MISSING 2) SEAL COVERS ON OUTSIDE OUTLETS 3) ALL OUTSIDE OUTLETS MUST BE GFCI PROTECTED (NORTH IS NOT) 4) WATER HEATER T&P LINE MUST EXHAUST 18-6" ABOVE GROUND 5) SEAL HOLE IN EVE AT NORTHWEST CORNER OF BUILDING 6) PROVIDE 526 #2 ADDRESS ON UNIT 7) NO ACCESS TO PROPERTY |
| 05/21/2002 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0920* |
| 01/16/2002 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) 5/8" TYPE CROSS DRYWALL MUST EXTEND FLOOR TO CEILING BEHIND EXERCISE ROOM BATH 2) EXERCISE ROOM BATH CEILING REQUIRES 2 LAYERS OF 5/8" TYPE CROSS 3) ALL OK BUT WEST WALL OF GARAGE STORAGE AND BATH |