Permit: T01CM03080

Parcel: 134243250


Addresses:

1031 S COLGATE DR

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
08/30/2001 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection 0000*/ 1) FTGS NOT READY 2) NEED TO TIE SLAB, OR STEM (HOWEVER YOUR DOING YOUR POUR) TOGETHER YOU NEED VERTICAL REBAR 4' ON CENTER MINIMUM
08/29/2001 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*/ 1) SEE LAST INSPECTION
08/28/2001 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION NO SAN TEES LYING FLAT, USE A COMBO AT CLOSET BEND 2) YOU WANT TO FLAT VENT THE SHOWER ROLL THE VENT FITTING TO UPPER 1/3 OF HORIZONTIAL DRAIN PIPE 3) OK TO COVER SEWER UP TO HOUSE WALL LINE ONLY
08/22/2001 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*/ 1) NO PLAN/PERMIT POSTED 2) YOU HAVE SOME PLUMBING, PROBLEMS WITHOUT SEEING THE PLANS 3) YOU NEED TO VENT EACH TRAP ARM, USE LONG SWEEP 90 DEGREE AT VERTICAL TO HORIZONTAL AND HORIZONTAL TURNS OF DIRECTION, NO SAN TEES LYING FLAT BLDG CO.