Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/29/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/24/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) YOU NEED 3/4" WATER SUPLY LINE FOR YOUR NEW BATHROOM. YOU CAN TAP OFF THE 3/4" TO SUPPLY TWO FIXTURES. THEN RETURN BACK TO 3/4" TO TAP 1/2 OFF FOR TWO MORE FIXTURES 2) APPROVE FAN BOX, REMOVE BOX EXTENSION, LOWER FAN BOX 1/2 BELOW FRAMING 3) MAKE SURE YOUR HVAC UNIT DOESN'T EXCEED 20 AMPS YOU RAN A #2 ROMEX FOR THAT CIRCUIT 4) BATHROOM OUTLET TO BE ON A SEPERATE 20 AMP CIRCUIT 5) NEED A SMOKE DETECTOR IN BEDROOM |
| 11/09/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK TO CONTINUE |
| 11/06/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |