Permit: T01CM03080

Parcel: 134243250


Addresses:

1031 S COLGATE DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/29/2002 FRAMING Approved IVRS - Inspection 0000*
01/24/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) YOU NEED 3/4" WATER SUPLY LINE FOR YOUR NEW BATHROOM. YOU CAN TAP OFF THE 3/4" TO SUPPLY TWO FIXTURES. THEN RETURN BACK TO 3/4" TO TAP 1/2 OFF FOR TWO MORE FIXTURES 2) APPROVE FAN BOX, REMOVE BOX EXTENSION, LOWER FAN BOX 1/2 BELOW FRAMING 3) MAKE SURE YOUR HVAC UNIT DOESN'T EXCEED 20 AMPS YOU RAN A #2 ROMEX FOR THAT CIRCUIT 4) BATHROOM OUTLET TO BE ON A SEPERATE 20 AMP CIRCUIT 5) NEED A SMOKE DETECTOR IN BEDROOM
11/09/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) OK TO CONTINUE
11/06/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*