Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/16/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/15/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) FHA STRAP DOUBLE TOP PLATE AT DRYER VENT AND KITCHEN HOOD VENT 2) FIREBLOCK HALLWAY AT CEILING LIGHT 3) DAMPERS AT EXHAUST FANS 4) SHEAR TRANSFER AT GARAGE NOT ADEQUATE PROVIDE POSITIVE CONNECTION |
| 08/14/2001 |
FRAMING |
|
Denied |