Date Description Inspector Results Comments
08/27/2001 FRAMING Approved IVRS - Inspection 0000*
08/24/2001 FRAMING Denied IVRS - Inspection 0999*1.) FRAME 16 OK WILL APPROVED ONCE SCREEN IS REMOVED FROM TOP DRYER VENT.
08/22/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE DOUBLE STUDS AT GIRDER TRUSS GARAGE 2) MISSING HOLDOWN AT GARAGE SHEARWALL AND BOLT MISSING 3) BLOCK MECHANICAL THREE SIDES AT GARAGE 4) MISSING FLAPPER IN FAN AT LAUNDRY ROOM 5) REMOVE SCREEN FROM DRYER VENT 6) ADD TWO MORE STUDS TO LEFT SIDE OF WINDOW AT GREAT ROOM WEST SIDE