Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/27/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/24/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*1.) FRAME 16 OK WILL APPROVED ONCE SCREEN IS REMOVED FROM TOP DRYER VENT. |
| 08/22/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE DOUBLE STUDS AT GIRDER TRUSS GARAGE 2) MISSING HOLDOWN AT GARAGE SHEARWALL AND BOLT MISSING 3) BLOCK MECHANICAL THREE SIDES AT GARAGE 4) MISSING FLAPPER IN FAN AT LAUNDRY ROOM 5) REMOVE SCREEN FROM DRYER VENT 6) ADD TWO MORE STUDS TO LEFT SIDE OF WINDOW AT GREAT ROOM WEST SIDE |