Permit: T01CM03020

Parcel: 129062940


Addresses:

2926 E BEVERLY DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/31/2001 FRAMING Approved IVRS - Inspection 0000*
08/06/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) NEED 1" CLEARANCE AT FLUE PIPE 2) NEED GROUND RODS INSTALLED FOR CABLE DROP 3) COMPLETE FINAL TIE IN ON MECHANICAL
07/31/2001 FRAMING Denied 1) WATER HEATER FLUE NEEDS 1" CLEARANCE FROM COMBUSTIBLES MATERIALS 4) UFER BROKE 5) REVISE SITE PLAN ADD STORAGE SHED AND CARPORT
07/20/2001 FRAMING Denied IVRS - Inspection 0999*1.) REVISE PLANS TO SHOW AS BUILT. FRAMING OR BUILD ALL BEARING AND PARTITION WALLS PER PLAN. 2.) PLUMBING MUST BE INSIDE FRAMED WALL. 3.) PLUMBING & ELECTRIC IN OFFICE ALONG TOP OF BEARING WALL MUST BE MOVED TO PROTECTED LOCATION. 4.) N.W. CORNER AT OFFICE HAS 2 RAFTERS THAT ARE NOT PLACED ON A STRUCTURAL HEADER.