Permit: T01CM02957

Parcel: 137338130

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/01/2001 FRAMING Approved IVRS - Inspection 0000*
07/31/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) ROOF NOT DRIED IN FLASHING NOT INSTALLED AT PENETRATIONS 2) PROTECT ROMEX CABLE AT GARAGE BACK WALL 3) BLOCK AND STRAP SHEARWALL GARAGE BACK DOUBLE TOP PLATE COMPLETELY CUT OUT 4) NO POWER TO LAUNDRY EXHAUST FAN 5) GROUND ALL METALIC BOXES AND KNOCK OUTS 6) ISOLATE FLEX DUCT FROM GUSSET PLATES 7) BLOCK UNDER ATTIC ACCESS PLATFORM 8) OSB RUNS PARALLEL TO
TRUSS WEBS