Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/11/2001 |
BUILDING - FINAL |
|
Denied |
1) SOUTHWEST SHEAT ADDITION IS STRUCTUALLY UNSOUND OVERSPAN AND IMPROPERLY SUPPORTED RATERS AND ROOF SYSTEM, UNTREATED LUMBER IN CONTACT WITH SOIL 2) EXTERIOR SHEATHIN ON EAST, WEST AND SOUTH SIDE OF STRUCTURE CANNOT BE IN CONTACT WITH SOIL 3) SOIL MUST PROVIDE A MINIMUM OF 2 PERCENT SLOPE AWAY FROM HOUSE FOR 5 FEET 4) SOUTHEAST COVERED PATIO RAFTERS HANGING FROM ORIGIANL FACING SOUTHERN 22' OF HOUSE 5) ELECTRIC OUTLETS REQUIRED WITHIN 6' OF EITHER SIDES OF DOORS AND EVERY 12' THERE AFTER AND ON ANY WALL 2' OR WIDER 6) CLOTHES WASHER DRAIN NOT PROPERLY PLUMBED, REQUIRES 2" DRAIN WITH A "P" TRAP 7) ELECTRIC SUB PANEL NOT PROPERLY INSTALLED, EXPOSED CABLES BELOW 8' ALSO REQUIRES AND ISOLATED NEUTRAL BAR 8) BEAMS IN DINING ROOM APPEAR TO BE SAGGING PROVIDE DETAIL OF INSTALLATION 9) GAS FLEX LINE CANNOT BE INSIDE WALL CAVITY 10) ALL BEDROOMS AND HALLS OR ROOMS LEADING TO BEDROOMS MUST HAVE AT LEAST BATTERY OPERATED SMOKE DETECTORS 11) 8' OF DINNING ROOM HAS CEILING LESS THAN 7' HIGH 12) BEDROOM 3 AND FAMILY ROOM HAVE NO HEAT |