Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM02843
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/19/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
09/18/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) DOWN STAIR W/C HAS LESS THAN 15" TO SIDE FROM CENTER LINE SEE ITEM 5 9/14/01 2) PROVIDE WHOLE HOUSE DWV WATER TEST PER UPC SECTION 712.2 3) PORCH LEDGER NOT CLIPPED SEE 14/SD3 4) REFEE |
|
09/14/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) ANCHOR BOLTS LOOSE THROUGHOUT 2) WATER HEATER T&P LINE MUST EXHAUST BETWEEN 6-18 INCHES ABOVE GRADE. TO LOW 3) GARAGE #4 SHEAR WALL REQUIRES NAILS AT 4" ON CENTER 4) 4/SD3 NOT COMPLIED 5) DOWN STAIR W/C REQUIRES 15" SIDE CLEARANCE IF FLOOR IS CUT PROVIDE ENGINEERS APPROVED REPAIR 6) 4 SWITCH ELECTRIC BOX MUST BE SECURE 2 ENDS 7) 4 EACH 2 X POST REQUIRED AT GARAGE WET WALL PER NOTE 34 8) ARCH REQUIRES DOUBLE 2 X POST SOUTH END 9) TO TIGHT OF RADIUS FOR DUCT AT LIVING ROOM WALL 10) TRUSSES IN LIVING ROOM NOT PROPERLY BEARING ON HANGERS AT G.L.B.-SEE SIMPSON INSTALLATION INSTRUCTIONS 11) PROVIDE A WHOLE HOUSE WATER TEST ON DWV PER UPC SECTION 712.2 12) ELECTRIC NOT ALLOWED IN RETURN AIR PLENIUM 13) MECHANICAL SUPPLY DUCT RESTRICTED AT 2ND FLOOR CHASE 14) EXTERIOR WALL PLATES NOT NAILED PER PLAN OR CODE 15) 14/SD3 NOT COMPLIED WITH 16) STOPPED INSPECTION 17) NEXT FAILURE WILL BE CHARGED A RE-INSPECTION FEE FOR EACH TRADE FAILING | |
09/11/2001 | FRAMING | Denied | 1) ISOLATE VENT AT GARAGE 2) PROVIDE 1" MINIMUM CLEARANCE AT FLUE AT GARAGE 3) SECURE PLUMBING IN 2ND LOWER FLOOR 4) PROVIDE FIRE BLOCK AT 2ND FLOOR VENT FRAME 5) CONNECT ALL GROUNDS |