Permit: T01CM02825

Parcel: 141147970

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/02/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/25/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) REMOVE SHINERS FROM GARAGE SOFFIT AREA 2) ADD LEDGER CLIPS TO ANGLED LEDGERS (HIP) AT BAY 3) OSB NOT NAILED UNDER 1ST FLOOR NORTHEAST HIP TRUSS WHERE IT MEETS THE LEDGER 4) ADD A-35'S TO NORTH AND SOUTH PATIOR FASCIA BOARDS (RAFTERS)
09/21/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NORTHWEST BEDROOM-TRUSS BRACKET HAS NO NAILER AT THE DUCT BOOT 2) OSB NOT NAILED IN 2 SPOTS ON 2ND FLOOR 1/2 WALL, UNDER FAR NORTH ROOF PLANE 3) NO TC CLIPS ON SCISSOR TRUSSES 4) ROOF NOT NAILED ALONG GARAGE SOFFIT AREA 5) A-35'S IMPROPERLY INSTALLED ON REAR BAY 1ST FLOOR LEDGER 5) INSTALL A-35'S ON NORTH AND SOUTH PATIO FASCIA BOARDS (RAFTERS)