Permit: T01CM02822

Parcel: 141146400

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/25/2001 FRAMING Approved IVRS - Inspection 0000*
07/24/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) NUMBERS 2, 5 AND 8 NOT DONE
07/23/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) STRAP TOP PLATES WHERE NOTCHED FOR HVAC LINES AND ELECTRIC HOMERUNS 2) HEADER OFF CUT STUDS IN SHEARWALL AT MAIN TRUNK PENETRATIONS 3) NO WATER PRESSURE 4) MOVE S.D. IN FRONT BEDROOM 5) SHIM HEADERS 6) USE COPPER AND BRASS SCREWS IN COPPER PIPE BRACKETS 7) MOVE WIRE OFF HOT WATER PIPE AT HEATER 8) CORRECT MIS- NAILED TC CLIPS 9) NO GAS PIPING IN YET