Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM02779

Parcel: 137336990


Addresses:

1575 W JOYCE LOU DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/19/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
07/17/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) 8 X 10 GUSSET AT 3 GABLE ENDS NOT PLATES INSTALLED 2) PROVIDE KICKERS UNDER RAFTERS AT OVER FRAME SHEET SEE SD2/9 3) PROVIDE 1/8" GAP AT ROOF SHEATHIN ENDS/EDGES