Permit: T01CM02741

Parcel: 133095500


Addresses:

1680 N MAGUIRE AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/14/2001 FRAMING Approved IVRS - Inspection 0000*
09/10/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) TEMP/POWER MISSING PANEL RISER 2) HPAD232 ON NORTH SIDE OF BLDG, MISSED THE SHEARWALL 3) MISSING SHEAR OSB REAR WALL P-1 4) BLOCK ALL MECHANICAL DUCTS 5) MISSING PLUMBING ITEMS NOT COMPLETE, WATER TEST 6) LOOSE BOTTOM PLATES AT FRONT DOOR 7) MISSING BLOCKS AT GARAGE SOFFIT 8) 1" CLEAR ON FURNACE FLUE TO COMBUSTIBLES 9) NAIL SHEAR TRANSFER (2 WALLS) TO ROOF SEE DETAIL 15/DT1