Permit: T01CM02718

Parcel: 141147830

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/24/2001 FRAMING Approved IVRS - Inspection 0000*
07/23/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) STRAP BOTH PLATES AND SCREW ALL HOLES 2) COPPER PIPE BRACKET AT KITCHEN SUPPLY PIPE, NEEDS COPPER SCREWS-NOT STEEL
07/20/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT HVAC LINES 2) STRAP DUCT AWAY FROM FURNACE FLUE 3) SUPPORT VENT 90 DEGREES IN LAUNDRY FROM BEING PUSHED DOWN 4) NEED COPPER OR BRASS SCREWS IN COPPER BRACKET AT KITCHEN SUPPLY PIPE
07/19/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) FHA STRAPS NEEDED TOP PLATES AT GAS LINE, AT 220 LINE, STUD AT 220 LINE AND TOP PLATES AT HVAC LINES 2) SHIM HEADERS 3) STRAP INSIDE OF BOTTOM PLATE AT KITCHEN SINK VENT 4) COPPER PIPE BRACKET AT KITCHEN SUPPLY PIPE, NEEDS COPPER SCREWS-NOT STEEL 5) GROUT TUB DRAIN HOLES 6) NO LEDGER AT TOP OF FRONT DOOR TRUSSES 7) NO WATER PRESSURE 8) SUPPORT LAUNDRY VENT 90 DEGREE 9) A-35'S IMPROPERLY INSTALLED AS ENTRY DORMER LEDGER 10) WRONG PLAN ON SITE