Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/24/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/23/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP BOTH PLATES AND SCREW ALL HOLES 2) COPPER PIPE BRACKET AT KITCHEN SUPPLY PIPE, NEEDS COPPER SCREWS-NOT STEEL |
| 07/20/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT HVAC LINES 2) STRAP DUCT AWAY FROM FURNACE FLUE 3) SUPPORT VENT 90 DEGREES IN LAUNDRY FROM BEING PUSHED DOWN 4) NEED COPPER OR BRASS SCREWS IN COPPER BRACKET AT KITCHEN SUPPLY PIPE |
| 07/19/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FHA STRAPS NEEDED TOP PLATES AT GAS LINE, AT 220 LINE, STUD AT 220 LINE AND TOP PLATES AT HVAC LINES 2) SHIM HEADERS 3) STRAP INSIDE OF BOTTOM PLATE AT KITCHEN SINK VENT 4) COPPER PIPE BRACKET AT KITCHEN SUPPLY PIPE, NEEDS COPPER SCREWS-NOT STEEL 5) GROUT TUB DRAIN HOLES 6) NO LEDGER AT TOP OF FRONT DOOR TRUSSES 7) NO WATER PRESSURE 8) SUPPORT LAUNDRY VENT 90 DEGREE 9) A-35'S IMPROPERLY INSTALLED AS ENTRY DORMER LEDGER 10) WRONG PLAN ON SITE |